General precautions
38
Power connection
Power capacity
Determine the power capacity with reference to specification lists and wiring diagrams.
(Be sure to install a Molded Case Circuit Breaker (MCCB) suitable for the capacity at the
main power supply.)
Rotation direction
OIL MATIC needs to be connected to the power supply such that an oil pump and a fan
motor in OIL MATIC make positive rotation. Since input terminals of the OIL MATIC power
switch are located in order of phases R, S, and T from the left side, connecting the phases
R, S, and T of the three-phase power supply to each of the terminals makes the rotation in
positive direction. (Since OIL MATIC is equipped with a reverse-phase protection relay, it is
not started in case of reverse phase.)
Washing and cleaning
Wash the air filter regularly, at least twice a month (warm water, air-washing, etc.), to prevent it
from being clogged. (Also, clean the condenser fin unit at least once a year.)
About OIL MATIC series V and KTV models
Reservoir tank sizes
A reservoir tank in which the OIL MATIC series V and
KTV machines are installed will have larger plane
dimensions than OIL MATIC and the tank depth shall
be determined from the right table. Take into
consideration that the temperature will be
well-controlled if the tank capacity is equal to or larger
than three times the flow rate (L/min) of the liquid sent
from this tank.
(Note 1) A too small tank interferes with vortex motion and reduces the cooling capacity.
Liquid level height
Keep the liquid level to the height that always makes the space between the bottom of a
chassis of the OIL MATIC series KTV/V models and the liquid level inside the tank, to be
30-100mm.
(Note 2) If the liquid level becomes lower than the specified level, then there is a possibility that dew is formed on the
cooling coil exposed in space and moisture may be mixed into the liquid. The low liquid level makes the cooling coil
exposed, which disables cooling of the liquid. For the OIL MATIC machines equipped with a heater, pay particular
attention to the liquid level to prevent the heater from operating without water, which is very dangerous.
About water-cooled condenser
To use a water-cooled condenser-type OIL MATIC, piping work for
passing coolant, which is used to radiate condensation heat, will be
needed. The separate table shows coolant pipe diameters and required
flow rates.
*In terms of coolant quality, use soft water that causes little adhesion of
scales.
Model
Coolant pipe diameter
Coolant inlet
temperature
Required flow
rate of coolant
L/min or more
Inlet Outlet
Model 38 1B 1B
At 25°C 30
At 34°C 60
Model 22 3/4B 3/4B
At 25°C 19
At 34°C 42
Model 15,
model 11
3/4B 3/4B
At 25°C 13
At 34°C 30
Model 7.5,
model 5
1/2B 1/2B
At 25°C 7.5
At 34°C 18
Model 3 1/2B 1/2B
At 25°C 6
At 34°C 12
About “OIL MATIC for coolant”
As the coolant for controlling temperature of the “OIL MATIC for
coolant,” use clean coolant filtered by a magnet separator, filter, etc. to
prevent failures caused by clogging of cooler, circulation pump, etc. from
occurring.
Introduction of related products
Controls temperature of
mold’s heat medium (oil, water) with
high precision
Automates and streamlines
“transportation”
in machine tool / assembly
lines
For more info
KANTO SEIKI
Search
Model Tank depth
KTV-3, V300 350m/m or more
KTV-5
400m/m or more
KTV-7.5, V750
KTV-11
KTV-15, V1500
500m/m or more
KTV-22, V2200